• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
The Egyptian Journal of Plastic and Reconstructive Surgery
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 49 (2025)
Volume Volume 48 (2024)
Volume Volume 47 (2023)
Volume Volume 46 (2022)
Volume Volume 45 (2021)
Volume Volume 44 (2020)
Issue Issue 4
Issue Issue 3
Issue Issue 2
Issue Issue 1
Volume Volume 43 (2019)
Volume Volume 42 (2018)
Ayad, H., Sadaka, M. (2020). The Septum-Based Superomedial Pedicle Technique in Reduction Mammoplasty. The Egyptian Journal of Plastic and Reconstructive Surgery, 44(2), 319-324. doi: 10.21608/ejprs.2020.113491
Hashem Mohamed Ayad; Mohamed Saad Sadaka. "The Septum-Based Superomedial Pedicle Technique in Reduction Mammoplasty". The Egyptian Journal of Plastic and Reconstructive Surgery, 44, 2, 2020, 319-324. doi: 10.21608/ejprs.2020.113491
Ayad, H., Sadaka, M. (2020). 'The Septum-Based Superomedial Pedicle Technique in Reduction Mammoplasty', The Egyptian Journal of Plastic and Reconstructive Surgery, 44(2), pp. 319-324. doi: 10.21608/ejprs.2020.113491
Ayad, H., Sadaka, M. The Septum-Based Superomedial Pedicle Technique in Reduction Mammoplasty. The Egyptian Journal of Plastic and Reconstructive Surgery, 2020; 44(2): 319-324. doi: 10.21608/ejprs.2020.113491

The Septum-Based Superomedial Pedicle Technique in Reduction Mammoplasty

Article 11, Volume 44, Issue 2, April 2020, Page 319-324  XML PDF (16.67 MB)
Document Type: Original Article
DOI: 10.21608/ejprs.2020.113491
View on SCiNiTO View on SCiNiTO
Authors
Hashem Mohamed Ayad email ; Mohamed Saad Sadaka
The Department of Plastic and Reconstructive Surgery, Faculty of Medicine, Tanta University
Abstract
Background: In this study, we present our technique of
the septum-based superomedial pedicle reduction mammoplasty
using an inverted T scar pattern. It is based on the
Wuringer's horizontal breast septum, through which run the
main neurovascular supply to the nipple-areola complex
(NAC).
Patients and Methods: The study included 35 cases with
bilateral breast hypertrophy. The mean suprasternal notch to
nipple (SSN-N) distance in our cases was 39.7±5.6cm. The
mean nipple elevation in our cases was 17.9±4.6cm. Our mean
resection weight was 764±160 grams per side. We had 6 cases
with resection weight exceeding 1500 grams per side.
Results: We had no cases of partial or total necrosis of
the NAC. Immediate postoperative breast sensation was
preserved in 26 cases and was impaired in 9 cases but it was
regained spontaneously within 6 months.
Conclusion: The septum-based superomedial pedicle
technique of reduction mammoplasty is safe technique with
improved NAC vascularity and sensation, even in cases of
gigantomastia, owing to the preservation of the important
neurovascular structures related to the breast septum.
Keywords
Breast; Reuction; Septum
Main Subjects
Aesthetics
References
Savaci N.: Reduction Mammoplasty by the Central Pedicle,
Avoiding a Vertical Scar. Aesth. Plast. Surg., 20: 171,
1996.
2- Dancey A., Khan M., Dawson J. and Pearl F.: Gigantomastia,
a classification and review of the literature. J.
Plast. Reconstr. Aesthet. Surg., 61: 493, 2008.
3- Movassaghi K., Liao E.C., Ting V., Matros E., Morris
D.J., Orgill D.P. and Pribaz J.J.: Eliminating the Vertical
Scar in Breast Reduction- Boston Modification of the
Robertson Technique. Aesthet. Surg. J., 26: 687, 2006.
4- Thorek M.: Possibilities in the reconstruction of the human
form 1922. Aesthetic Plast. Surg., 13: 55, 1989.
5- Karsidag S., Akcal A., Karsidag T., Yesiloglu N., Yesilada
A.K. and Ugurlu K.: Reduction mammaplasty using the
free nipple-graft vertical technique for severe breast
hypertrophy: improved outcomes with the superior dermaglandular
flap. Aesthetic Plast. Surg., 35: 254, 2011.
6- Fırat C., Gurlek A., Erbatur S. and Aytekin A.H.: An
autoprosthesis technique for better breast projection in
free nipple graft reduction mammaplasty. Aesthetic Plast.
Surg., 36: 1340, 2012.
7- Wuringer E., Mader N., Posch E. and Holle J.: Nerve and
vessel supplying ligamentous suspension of the mammary
gland. Plast. Reconstr. Surg., 101: 1486, 1998.
8- Wuriner E.: Refinements of the central pedicle breast
reduction by application of the ligamentous suspension.
Plast. Reconstr. Surg., 103 (5): 1400, 1999.
9- Lugo L.M., Prada M., Kohanzadeh S., Mesa J.M., Long
J.N. and de la Torre J.: Surgical outcomes of gigantomastia
breast reduction superomedial pedicle technique: A 12-
year retrospective study. Ann. Plast. Surg., 70: 533, 2013.
10- Blondeel P.N., Hamdi M., Van de Sijpe K.A., Van Landuyt
K., Thiessen F.E. and Monstrey S.: The latero-central
glandular pedicle technique for breast reduction. Br. J.
Plast. Surg., 56: 348, 2003.
11- van Deventer P.V.: The blood supply to the nipple-areolar
complex of the human mammary gland. Aesthetic Plast.
Surg., 28: 393, 2004.
12- van Deventer P.V. and Graewe F.R.: The blood supply of
the breast revisited. Plast. Reconstr. Surg., 137: 1388,
2016.
13- Corduff N., Rozen W.M. and Taylor G.I.: The superficial
venous drainage of the breast: A clinical study and implications
for breast reduction surgery. J. Plast. Reconstr.
Aesthet. Surg., 63: 809, 2010.
14- BucariaV., Elia R. and Maruccia M.: Why Choose the
324 Vol. 44, No. 2 / The Septum-Based Superomedial Pedicle Technique in Reduction Mammoplasty
Septum-Supero-Medial (SSM)-Based Mammaplasty in
Patients with Severe Breast Ptosis: An Anatomical Point
of View. Aesthetic Plast. Surg., 42 (6): 1439, 2018.
15- Karacaoglu1 E. and Zienowicz R.J.: Septum-Inferior-
Medial (SIM)-Based Pedicle: A Safe Pedicle with Well-
Preserved Nipple Sensation for Reduction in Gigantomastia.
Aesthetic Plast. Surg., 41: 1, 2017.
16- van Deventer P.V. and Graewe F.R.: Enhancing Pedicle
Safety in Mastopexy and Breast Reduction Procedures:
The Posteroinferomedial Pedicle, Retaining the Medial
Vertical Ligament of Wuringer. Plast. Reconstr. Surg.,
126: 786, 2010.
17- Al-Shahat O.A., Al-Refae A. and Taha A.: Würinger's
Septum Based Inferior Pedicle Reduction Mammaplasty.
Egypt. J. Plast. Reconstr. Surg., 35: 153, 2011.
18- Bayramiçli M.: The Central Pillar Technique: A New
Septum-Based Pedicle Design for Reduction Mammaplasty.
Aesthet. Surg. J., 32 (5): 578, 2012.
19- Uslu A., Korkmaz1 M.A. and Surucu A., Karaveli A.,
Sahin C., and Ataman M.G.: Breast Reduction Using the
Superomedial Pedicle- and Septal Perforator-Based Technique:
Our Clinical Experience. Aesthetic Plast. Surg.,
43 (1): 27, 2019.
20- Portincasa A., Ciancio F. and Cagiano L.: Septum-
Enhanced Mammaplasty in Inferocentral Pedicled Breast
Reduction for Macromastia and Gigantomastia Patients.
Aesthetic Plast. Surg., 41 (5): 1037, 2017.
21- Kelahmetoglul O., Firinciogullari R. and Yagmur C.:
Combination of Wuringer's Horizontal Septum and Inferior
Pedicle Techniques to Increase Nipple-Areolar Complex
Viability During Breast Reduction Surgery. Aesthetic
Plast. Surg., 41 (6): 1311, 2017.
22- Hamdi M., Landuyt K.V. and Tonnard P.: Septum-Based
Mammaplasty: A Surgical Technique Based on Wuringer's
Septum for Breast Reduction. Plast. Reconstr. Surg., 123:
443, 2009.
23- Le Roux C.M., Kiil B.J., Pan W., Rozen W.M. and Ashton
M.W.: Preserving the neurovascular supply in the Hall-
Findlay superomedial pedicle breast reduction: An anatomical
study. J. Plast. Reconstr. Aesthet. Surg., 63: 655,
2010.

Statistics
Article View: 341
PDF Download: 1,034
Home | Glossary | News | Aims and Scope | Sitemap
Top Top

Journal Management System. Designed by NotionWave.